Controls the rejection of bad samples from the COM estimate
"
com.<xxx>"
parameters that control the rejection of bad detectors based on the gain and correlation coefficients for the fit of
the common-mode signal to each detector (good at identifying bolo signals with bizarre gains, or shapes if they
have for example steps in them). These are basically sigma-clippers; outliers are removed at the given
threshold and then new means and sample standard deviations are measured until convergence. The
time axis is divided up into one or more equal sized boxes, and a separate fit is performed for
each box. If you wish to completely disable the flagging of outlier bolometers compared with the
common-mode, simply set com.noflag=1. The flags may be frozen after a specified number of iterations - see
parameter "
com.freeze_flags"
. [0.2]