Description:
Specifies the number of time slices used to determine the noise level in a section of a bolometer
time stream. If zero, then the whole bolometer time stream is used, and each bolometer
has only one variance value. If non-zero, each bolometer time stream is divided up into
boxes containing the specified number of time slices, and a separate variance is found
for each box. This variance is then used for each sample in the box, so each bolometer
ends up with a variance for every time slice. Negative values are interpreted as number of
seconds, and positive values as a number of down-sampled time slices. Note, very small
box sizes may produce unrepresentative noise levels, and there is a hard minimum of 101
on the number of downsampled time slices in a noise box. Also, if the number of time
slices in the data is smaller than two times the requested box size, then a single noise value
is used for each bolometer. [-15]
Type:
real SMURF Usage
MAKEMAP, CALCQU
Copyright © 2012 University of British Columbia & the Science & Technology Facilities Council