CALIBRATE_SCUBA2_DATA
Calibrate SCUBA-2 data
Description:
Calibrate SCUBA-2 data
with a given or default FCF. The units of the input data are checked and the appropriate default FCF
chosen. The output files have a suffix of _cal.
This recipe may be used to convert between different (known) calibration types, e.g., from
mJy/arcsec2
to mJy/beam and vice versa.
Notes:
-
The input data must not have the same units as the desired calibration.
-
All input data will have the same calibration applied.
-
The FCF FITS header will be updated with the value used to calibrate the data. The units will be in the
comment.
Available Parameters :
The following recipe parameters can be set via the -recpars
option:
FCF
FCF to use to calculate data. The same value is used for all files. The
standard SCUBA-2 FCF will be used if not given.
FCF_CALTYPE
FCF type for determining
the output units. May be BEAM (default) or ARCSEC