Processing math: 6%

JITTER_SELF_FLAT_CATALOGUE

Reduces a “standard jitter” photometry observation using object masking, and produces a catalogue of all sources in the field

Description:

This script reduces a “standard jitter” photometry observation with near-infrared imaging data. It takes an imaging observation comprising jittered object frames and a dark frame to make a calibrated, untrimmed mosaic automatically.

It performs a null debiassing, bad-pixel masking, dark subtraction, flat-field creation and division, feature detection and matching between object frames, and resampling. See the “Notes” for further information.

Source extraction is performed only on the reduced mosaic, and uses EXTRACTOR. The results appear in $ORAC_DATA_OUT/catalogue_<group_number>.txt. No zero-point or airmass corrections are applied to the instrumental magnitudes.

This recipe works well for faint sources and for moderately crowded fields.

Notes:

Output Data

Parameters:

NUMBER = INTEGER
The number of frames in the jitter pattern. If not supplied the number of offsets, as given by FITS header NOFFSETS, minus one is used. If neither is available, 9 is the default. An error state arises if the number of jittered frames is fewer than 3. For observations prior to the availability of full ORAC, header NOFFSETS will be absent. []
USEVAR = LOGICAL
Whether or not to create and propagate variance arrays. [0]

Related Recipes

BRIGHT_POINT_SOURCE_CATALOGUE, JITTER_SELF_FLAT,
JITTER_SELF_FLAT_APHOT.

Implementation Status: